Boiler Reheater Temperature Control

Superheater and Reheater (SH and RH) |

This is also used for SH temperature control supplementing attem — peration (Figure 6.26). Gas Recirculation and Tempering. Flue gas from a boiler, ECON, and AH exit at 250-400°C and can be introduced back into the furnace, without interfering with combustion, for

Free Chat

3 Steps to Better Steam Temperature Control

2018-12-26 · precise temperature control because of frequent temperature set point changes, but this calls for a more rigorous measurement approach. Power plants commonly deploy direct wire redundant thermocouples which isn't a problem during steady state conditions since you can correlate temperature against pressure.

Free Chat

Boiler Tube Failure, Prevention and Control

2012-4-18 · boiler tube failures and fall into the following categories: – Operating practices – Maintenance practices – Engineering practices 6 State-of-the-Art Operating Practice • Major operating practices influencing boiler tube failure are: – Cycle water chemistry – Boiler, superheater and reheater temperature control – Combustion control

Free Chat

Parametric Identification of the Reheater of a Power

Existing methods of controlling the temperature of superheated steam in a power-plant boiler are analyzed. Judging from the quality indices that are obtained, the optimum control method for this purpose was determined to be the injection of natural condensate. It is shown that the temperature regime of the reheater of the boiler depends on the organization of the injection operation.

Free Chat

CCCT MIMO Controller with Compensator via Gain tuning

2010-7-19 · Conventional control of steam temperature using feedback cascade PID controller in the superheater and the reheater of thermal power plant is known to be efficient to compensate disturbance. However, time constant of steam temperature control of superheater and reheater is bigger than other control

Free Chat

3 Steps to Better Steam Temperature Control

2018-12-26 · precise temperature control because of frequent temperature set point changes, but this calls for a more rigorous measurement approach. Power plants commonly deploy direct wire redundant thermocouples which isn't a problem during steady state conditions since you can correlate temperature against pressure.

Free Chat

Superheater Steam Temperature Control for a 300MW

2015-8-11 · Detailed control tests are carried out on a full-scope simulator for a 300MW coal-fired power generating unit. It is shown that the temperature control is greatly improved with the IDNCs compared to the original cascaded PID control scheme. Index Terms—Boiler control, feedforward control, inverse

Free Chat

_

() Boiler Reheater Temperature Control System Design Abstract Because the PID controller has the advantages of simple structure, easy realization, good robustness advantages, it is widely used in Boiler Reheater Temperature

Free Chat

(PDF)

temperature control for boilers designed for constant. heater and steam reheater temperature slightly increase. temperature at boiler pressure between 175 and 180 bar.

Free Chat

Steam Temperature Control | Control Notes

Steam temperature is one of the most challenging control loops in a power plant boiler because it is highly nonlinear and has a long dead time and time lag. Adding to the challenge, steam temperature is affected by boiler load, rate of change of boiler load, air flow rate, the combination of burners in service, and the amount of soot on the

Free Chat

623 ℃ -《》

XIA Jie, QIAN Yonggui. The primary practical application of reheater temperature 623 ℃ in ultra-supercritical П type boiler[J]. Boiler Technology, 2015, 46(1): 52-56. [4],,, . 1 000 MW

Free Chat

Boiler control -- "Reheater protection" trip |

2000-11-10 · It is not clear what you mean by Reheater Protection, so I will presume that you mean: 1) failure of the reheat temperature control logic; and 2) failure of the reheat loop piping, spray water and temperature control valves. No, the NFPA has no restriction! In general the factors to consider are protection of life and plant.

Free Chat

Mathematical Modelling of Reheater Section for Boiler

Mathematical Modelling of Reheater Section for Boiler Tube Leakage 3.4 Steam Temperature Control The nominal control of reheat steam temperature is carried out by tilting the burners. The superheater steam temperature is controlled by spraying water. Other

Free Chat

(PDF) Operation of Reheat Steam Temperature

The boilers used for this study were operated under sliding pressure mode; hence, reheat steam temperature control by spray is a common practice in subcritical boiler operations.

Free Chat

A Study on Vibration Control for Reheater Spray

The function of reheater spray piping (OD 3.5 inch, Sch 80) is to control boiler temperature. It receives water from feedwater pumps and supplies it to attemperator installed in the cold reheat line. It regulates boiler temperature by injecting feed water into the reheater when the boiler is overheated, but the line is not activated during the

Free Chat

Coal Boiler With Superheater - canaryimmo.net

2013-9-20 · 8-High temperature superheater, 9-High temperature reheater, 10-Low temperature superheater, 11-Low temperature reheater, 12-Economizer The boiler type is HG-1025/17.3-WM18, drum type with steam reheating. It has subcritical pressure of 17.3Mpa and natural circulation.

Free Chat

Intelligent modified predictive optimal control of

A modified predictive optimal control (MPOC) scheme based on neural network modeling and particle swarm optimization (PSO) techniques is proposed in this paper for reheater steam temperature (RST) control of a large-scale boiler unit. A recurrent neural network is trained to directly model the temperature dynamic response of the reheater system.

Free Chat

Boiler control -- "Reheater protection" trip |

2000-11-10 · It is not clear what you mean by Reheater Protection, so I will presume that you mean: 1) failure of the reheat temperature control logic; and 2) failure of the reheat loop piping, spray water and temperature control valves. No, the NFPA has no restriction! In general the factors to consider are protection of life and plant.

Free Chat

B1 Chapter 4 Flashcards | Quizlet

The control methods used for reheater temperature are the same as those used for _____ temperature control. Select one: A. boiler B. fuel gas C. superheater D. preheater. C. superheater. When the boiler is shut down, the air preheater should be inspected for signs of _____.

Free Chat

Boiler With Superheater - fsv-jugendfussball.de

2019-6-28 · Mainly used in the manufacture of large-scale boiler superheater, reheater and steam pipe. The maximum operating temperature of 650 ℃, for the boiler tube to allow the oxidation temperature of 705 ℃, 0Cr17Ni12Mo2 (equivalent to TP316, TP316H, SUS316TB, SUS316TP) is a common austenitic stainless steel heat. Read More